Inspection Detail
Inspection: 1308602.015 - Nationwide Boiler Inc
Inspection Information - Office: Fremont District Office
Site Address:
Nationwide Boiler Inc
42400 Christy St.
Fremont, CA 94538
Mailing Address:
42400 Christy St., Fremont, CA 94538
Union Status: NonUnion
SIC:
NAICS: 332410/Power Boiler and Heat Exchanger Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/25/2018
Emphasis:
Case Closed: 07/17/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1326932 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $14,400 | $0 | $0 | $450 | $0 | $14,850 |
| Current Penalty | $14,400 | $0 | $0 | $450 | $0 | $14,850 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203(A)(6) | 06/26/2018 | $450 | $450 | $0 | Z - Issued | |||
| 2. | 02001 | Serious | 3380(C) | 06/26/2018 | $14,400 | $14,400 | $0 | Z - Issued |
Investigation Summary
At 1:30 p.m. on April 7, 2018, Employee #1 was attempting to sandblast the rear door of a metal frame boiler at the company yard. The employee lost his balance and shot himself in the left arm with the sandblasting gun, which penetrated his left arm about one inch. He was transferred to a nearby hospital for treatment.
Keywords: Arm, Boiler, Door, Flying Object, Lost Balance, Sandblasting, Struck By
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1308602.015 | 49 | M | Hospitalized injury | Painting and paint spraying machine operators |