Inspection Detail
Inspection: 1307390.015 - Fm Technologies Group
Inspection Information - Office: Pr-E-San Juan 0257260
Site Address: 
			   Fm Technologies Group
			   Pr 833 Km 1.4 Los Frailes
Guaynabo, PR 00971
Mailing Address: 
			   1738 Calle Amarillo Esq. Ave. Lomas Verdes, Suite 102, San Juan, PR 00926
Union Status: NonUnion
SIC:
NAICS: 517110/Wired Telecommunications Carriers
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/07/2018
Emphasis:
Case Closed: 10/18/2018
| Type | Activity Nr | Safety | Health | 
|---|---|---|---|
| Inspection | 1345013 | Yes | |
| Accident | 1326234 | ||
| Inspection | 1313348 | Yes | |
| Inspection | 1307427 | Yes | |
| Inspection | 1307427 | Yes | 
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total | 
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 | 
| Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 | 
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 | 
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note | 
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100268 B07 | 09/27/2018 | 10/23/2018 | $2,500 | $5,000 | $0 | I - Informal Settlement | 
Investigation Summary
At 10:30 a.m. on April 7, 2018, an employee was leveling a telecommunications antenna. As the employee was lifting a tube to affix it into position, his shoulder contacted a live electrical line, measuring 13,000 volts. As a result, the employee was electrocuted.
Keywords: Antenna, Electrocuted, Power Lines, Telecom Work
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation | 
|---|---|---|---|---|---|---|
| 1 | 1307390.015 | 28 | M | Fatality | Telecomm: Line Installers And Repairers | 