Investigation Summary
On 3:30 p.m. on March 22, 2018, two employees were caught by an explosion of a hydrogen generator. Employee #1 suffered several fractures, internal injuries, loss of vision and hearing, and was hospitalized. Employee #2 suffered hearing loss.
Keywords: Explosion, Fracture, Hearing Loss
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1305988.015 | 60 | M | Non Hospitalized injury | Technicians, n.e.c. |