Powered by GoogleTranslate

Inspection Detail

Inspection: 1300797 - Empire Detroit Steel Division Of Cyclops Corp

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 1300797
Report ID: 0524700
Date Opened: 08/17/1984

Site Address:
Empire Detroit Steel Division Of Cyclops Corp
913 Bowman Street
Mansfield, OH 44901

Mailing Address:
, , 00000

Union Status: Union

SIC:3312

NAICS: 0 


Inspection Type: Planned

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/05/1984

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/06/1985


Related Activity
Type Activity Nr Safety Health
Accident 360557649
Complaint 70659354 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $810 $0 $0 $0 $0 $810
Current Penalty $405 $0 $0 $0 $0 $405
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 A 10/23/1984 10/26/1984 $405 $810 $0 11/07/1984 F - Formal Settlement  

Investigation Summary

Investigation Nr: 14513923
Event: 08/14/1984
BURNED BY HOT WATER FROM FURNACE COOLING LINE

THE EMPLOYEES WERE IN THE PROCESS OF CHANGING A 52 INCH WATER COOLED ELBOW ON THE TOP OF ELECTRIC ARC STEEL MELTING FURNACE #8. A PIPE ELBOW, USED FOR EMISSION CONTROL, HAD BEEN LEAKING WATER INTO THE FURNACE. THE ELBOW WAS REMOVED FROM THE FURNACE AND A NEW ONE PUT ON. THE NEW ONE WOULD NOT FIT. THEY HAD TO BURN A HOLE IN THE LOWER PART OF THE OLD ELBOW TO DRAIN IT, WELD THE LEAKS, AND PUT IT BACK ON THE FURNACE. THEY PLUGGED THE DRAIN HOLE BEFORE ALL THE WATER HAD DRAINED OUT. AS THEY WERE ATTEMPTINGTO HOOK UP THE 6 INCH SUPPLY AND DISCHARGE LINES, THE WATER IN THE FURNACE LINES HEATED RAPIDLY. STEAM WAS VENTING OUT THE 6"INCH LINES WHEN THEY GOT THE FIRST LINE ON. THIS TRAPPED THE STEAM INSIDE THE JACKET, CAUSING IT TO PUSH THE HEATED WATER OUT THE REMAINING 6 INCH PIPE. THE HOT WATER STRUCK EMPLOYEE #1 IN THE CHEST, CAUSING FATAL THIRD DEGREE BURNS. HE WAS STANDING DIRECTLY IN FRONT OF THE OPEN LINE. PROTECTIVE CLOTHING WAS NOT REQUIRED OR BEING USED.

Keywords: BURN, FURNACE, STEEL-MELTING FURN, STEAM, HOT WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1300797 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.