Inspection Detail
Inspection: 1297381.015 - 317718414 - Portland Container Repair Corporation
Inspection Information - Office: Or-E-Portland - Safety 1 1054111
Site Address:
317718414 - Portland Container Repair Corporation
9449 N Burgard Way
Portland, OR 97203
Mailing Address:
8316 N Lombard St Pmb 300, Portland, OR 97230
Union Status: NonUnion
SIC:7623
NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/16/2018
Emphasis:
Case Closed: 07/17/2018
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $1,225 | $0 | $0 | $0 | $0 | $1,225 |
Current Penalty | $1,225 | $0 | $0 | $0 | $0 | $1,225 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100147 C01 | 03/02/2018 | 03/08/2018 | $875 | $875 | $0 | Z - Issued | ||
2. | 01002 | Serious | OAR 437-002-0134(1)(A)(A) | 03/02/2018 | 03/08/2018 | $350 | $350 | $0 | Z - Issued |
Investigation Summary
At 3:15 p.m. on September 26, 2017, an employee was replacing a hydraulic valve on a Terex reach stacker. When loosening a hydraulic line at the valve, the line blew off and forced hydraulic fluid into the base of the employee's thumb. The employee was taken to the hospital where he was kept overnight for treatment.
Keywords: Hydraulic Fluid, Pressure Release, Thumb, Valve
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1297381.015 | 24 | M | Hospitalized injury | Welders and cutters |