Inspection Detail
Inspection: 1295382.015 - Ralph Tyeryar
Inspection Information - Office: Department Of Labor, Licensing And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
Ralph Tyeryar
3037 Marshall Hall Road
Bryans Road, MD 20616
Mailing Address:
7022 Sundays Lane, Frederick, MD 21702
Union Status: NonUnion
SIC:
NAICS: 238160/Roofing Contractors
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/14/2018
Emphasis: S:Electric
Case Closed: 09/12/2018
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1311166 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 3 | 1 | 4 | |||
Initial Penalty | $3,700 | $0 | $0 | $0 | $0 | $3,700 |
Current Penalty | $2,079 | $0 | $0 | $0 | $0 | $2,079 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260416 A01 | 05/22/2018 | 05/31/2018 | $756 | $1,400 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19260416 A03 | 05/22/2018 | 05/31/2018 | $756 | $1,400 | $0 | I - Informal Settlement | ||
3. | 01003A | Serious | 19260501 B10 | 05/22/2018 | 05/31/2018 | $567 | $900 | $0 | I - Informal Settlement | ||
4. | 01003B | Serious | 19260503 A01 | 05/22/2018 | 06/25/2018 | $0 | $0 | $0 | I - Informal Settlement | ||
5. | 02001 | Other | 19260405 G02 IV | 05/22/2018 | 05/31/2018 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 8:45 a.m. on February 15, 2018, Employee #1, employed by a roofing company, was tearing off the roof of an existing one-story commercial building that was being renovated. He was instructed to use a Milwaukee Sawzall reciprocating saw, Catalog Number 6519-30, Serial Number C25C3162702329, 12 amperes, 120 volts, to cut through metal conduit protruding approximately 16 inches above the roof's surface. The building owner had advised that the wires in the conduit were not energized. However, when Employee #1 cut through the insulation to the wires inside, he received an electric shock. Emergency medical technicians with an ambulance were parked outside the building, and they transported Employee #1 to the hospital, where he was examined and released.
Keywords: Conduit, Construction, Dismantling, Electric Saw, Electric Shock, Repair, Roof, Saw
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1295382.015 | 43 | M | Hospitalized injury | Roofers |