Inspection Detail
Inspection: 1293828.015 - Cj'S Sales And Service Of Ocala, Inc.
Inspection Information - Office: Savannah Area Office
Site Address:
Cj'S Sales And Service Of Ocala, Inc.
220 Retreat Village
Saint Simons Island, GA 31522
Mailing Address:
132 Ne 17th Place, Ocala, FL 34470
Union Status: NonUnion
SIC:
NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/08/2018
Emphasis: N:Amputate
Case Closed: 06/08/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1240377 | Yes | |
| Referral | 1307512 | Yes |
Investigation Summary
At 4:45 p.m. on February 6, 2018, an employee was working for a firm that repaired and maintained commercial and industrial machinery and equipment. He was inspecting a liquid petroleum gas (LPG)powered generator for oil leaks. His hand came into contact with a blade of the generator's fan. He sustained the partial amputation of the little finger on his right hand. The narrative did not say whether or not he was hospitalized.
Keywords: Amputated, Amputation, Electric Generator, Fan, Fan Blade, Finger, Hand, Maintenance, Struck Against, Struck By
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1293828.015 | 55 | M | Hospitalized injury |