Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1292252.015 - First Marine, Llc, A Division Of Western Rivers Boat Management, Inc., Assumed Name For Wrbm, Llc

Inspection Information - Office: Nashville Area Office

 

Inspection Nr: 1292252.015
Report ID: 0420100
Date Opened: 01/19/2018

Site Address:
First Marine, Llc, A Division Of Western Rivers Boat Management, Inc., Assumed Name For Wrbm, Llc
354 Hollanger Rd
Calvert City, KY 42029

Mailing Address:
354 Hollanger Rd, Calvert City, KY 42029

Union Status: NonUnion

SIC:

NAICS: 336611/Ship Building and Repairing


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/10/2018

Emphasis: L:Xboatprg

Case Closed: 07/23/2024


Related Activity
Type Activity Nr Safety Health
Accident 1306337
Inspection 1292344 Yes
Inspection 1292349 Yes
Inspection 1292350 Yes
Inspection 1292870 Yes
Inspection 1292870 Yes
Inspection 1304227 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 12 1 13
Current Violations 6 2 8
Initial Penalty $114,005 $0 $0 $2,033 $0 $116,038
Current Penalty $48,780 $0 $0 $9,163 $0 $57,943
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 07/17/2018 07/27/2018 $0 $12,934 $0 08/07/2018 F - Formal Settlement Citation has been deleted.
2. 01002A Serious 19150055 F03 07/17/2018 07/27/2018 $8,130 $8,130 $0 08/07/2018 F - Formal Settlement  
3. 01002B Serious 19150055 F04 07/17/2018 07/27/2018 $0 $0 $0 08/07/2018 F - Formal Settlement  
4. 01003 Serious 19150073 D 07/17/2018 $8,130 $8,130 $0 08/07/2018 F - Formal Settlement  
5. 01004 Serious 19150074 C02 07/17/2018 07/23/2018 $0 $8,130 $0 08/07/2018 F - Formal Settlement Citation has been deleted.
6. 01005 Serious 19150081 B01 IV 07/17/2018 07/27/2018 $8,130 $8,130 $0 08/07/2018 F - Formal Settlement  
7. 01006A Serious 19150089 B04 07/17/2018 08/10/2018 $8,130 $8,130 $0 08/07/2018 F - Formal Settlement  
8. 01006B Serious 19150089 B05 07/17/2018 08/10/2018 $0 $0 $0 08/07/2018 F - Formal Settlement  
9. 01006C Serious 19150089 B06 07/17/2018 08/10/2018 $0 $0 $0 08/07/2018 F - Formal Settlement  
10. 01006D Serious 19150089 M01 07/17/2018 08/10/2018 $0 $0 $0 08/07/2018 F - Formal Settlement  
11. 01007 Serious 19150089 O04 07/17/2018 08/10/2018 $8,130 $8,130 $0 08/07/2018 F - Formal Settlement  
12. 01008 Serious 19150089 Q01 07/17/2018 08/10/2018 $8,130 $8,130 $0 08/07/2018 F - Formal Settlement  
13. 01009 Serious 19150158 B02 07/17/2018 07/23/2018 $0 $10,163 $0 08/07/2018 F - Formal Settlement Citation has been deleted.
14. 01010 Serious 19150503 B02 II 07/17/2018 $0 $12,934 $0 08/07/2018 F - Formal Settlement Citation has been deleted.
15. 01011 Serious 19150503 B02 IV 07/17/2018 $0 $12,934 $0 08/07/2018 F - Formal Settlement Citation has been deleted.
16. 01012A Other 19150508 B01 07/17/2018 05/13/2020 $8,130 $8,130 $0 08/07/2018 F - Formal Settlement  
17. 01012B Other 19150508 B02 07/17/2018 05/13/2020 $0 $0 $0 08/07/2018 F - Formal Settlement  
18. 02001 Other 19040040 A 07/17/2018 $1,033 $2,033 $0 08/07/2018 F - Formal Settlement  

Investigation Summary

Investigation Nr: 102728.015
Event: 01/19/2018
One employee is killed and another hospitalized from tank ex

At 9:15 a.m. on January 19, 2018, Employee #1 was using a oxy/fuel gas cutting torch to cut a piece of metal being held by Employee #2. Earlier that morning, , around 7:03 a.m., Employee #1, a fitter, and Employee #2, a welder, boarded the William E Strait, a line haul vessel under repair. They found that the gas line for their cutting torch, which had been left inside the vessel in a room below the deck locker near the bow the day prior, had been turned on and a torch was not connected to the line. Oxygen and propylene flowed into the vessel for an unknown period of time. Employees #1 and 2 reported smelling gas throughout the boat. After turning off the gas, the two employees turned on two ventilation fans to remove the gas from the space, where the hose line was located. One was placed at the top of the stairs on the main deck, blowing into the space, and the second was placed in a port hole above the space, blowing outward. They vented the space for about an hour and a half until they could not smell gas anymore and then started work that involved cutting and welding without having the atmosphere tested. Inside of the room adjacent to where the open end of the gas line was located was an open 2,569 gallon potable water tank that was empty, which was connected, via a 4 inch pipe, to a 5,743 gallon potable water tank that was located in a space between the vessel's two engines in the lower engine room near the center of the vessel. Propylene and oxygen from the release entered into the forward portable water tank. At 9:16 a.m. Employee #2 was holding metal that Employee #1 was cutting with a cutting torch in front of the open port of the forward potable water tank, when both tanks exploded. Employee #1 suffered burns and trauma to his body, resulting in his death, while Employee #2 sustained burns to his face and arms, trauma to his body, and ruptured ear drums, which he was hospitalized.

Keywords: Burn, Ear, Explosion, Flammable Vapors, Hearing Loss, Oxygen, Torso

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1292252.015 52 M Fatality Welders and cutters
2 1292252.015 56 M Hospitalized injury Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close