Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1289554.015 - Boskovich Farms, Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 1289554.015
Report ID: 0950643
Date Opened: 12/15/2017

Site Address:
Boskovich Farms, Inc.
711 Diaz Avenue
Oxnard, CA 93030

Mailing Address:
P.O. Box 1352, Oxnard, CA 93032

Union Status: NonUnion

SIC:

NAICS: 111998/All Other Miscellaneous Crop Farming


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/13/2018

Emphasis:

Case Closed: 08/29/2019


Related Activity
Type Activity Nr Safety Health
Complaint 1276544 Yes
Complaint 1300780 Yes
Accident 1300782
Inspection 1288507 Yes
Inspection 1289562 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 1 4 5
Initial Penalty $0 $0 $0 $6,160 $0 $6,160
Current Penalty $7,650 $0 $0 $1,695 $0 $9,345
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3328(B) 06/13/2018 07/18/2018 $0 $1,275 $0 05/16/2019 O - Administrative Law Judge Order  
2. 01002 Other 5155(E) 06/13/2018 07/18/2018 $635 $1,275 $0 05/16/2019 O - Administrative Law Judge Order  
3. 01003 Other 5194(H)(1) 06/13/2018 07/18/2018 $1,060 $1,060 $0 05/16/2019 O - Administrative Law Judge Order  
4. 01004 Other 5194(H)(2)(E) 06/13/2018 07/18/2018 $0 $1,275 $0 05/16/2019 O - Administrative Law Judge Order  
5. 02001 Serious 3328(G) 06/13/2018 07/18/2018 $7,650 $1,275 $0 05/16/2019 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 106435.015
Event: 12/14/2017
Two employees are injured in release of chlorine gas

At 12:40 p.m. on December 14, 2017, two employees were sorting/packing produce on the tomato line, performing janitorial work, and overseeing the proper function of the produce lines. The Pulse Instruments EP500 Monitoring and Control System's automated citric acid injection controller for Line A had a malfunctioning solenoid and sensor that resulted in a drop in the water pH, and a subsequent release of chlorine gas from the disinfection water into the air in the production area. The employees complained of symptoms such as eye, throat and chest irritation and pain.

Keywords: Chest, Chlorine, Eye, Gas, Gas Leak, Throat

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1289554.015 27 M Non Hospitalized injury
2 1289554.015 39 M Non Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.