Inspection Detail
Inspection: 1289404.015 - 96693 - Ballman Roofing - Coating Llc Dba Ballman Exterior
Inspection Information - Office: Minnesota Department Of Labor And Industry
Site Address:
96693 - Ballman Roofing - Coating Llc Dba Ballman Exterior
1520 17th St Nw
Faribault, MN 55021
Mailing Address:
45668 Hwy 22, Kasota, MN 56050
Union Status: NonUnion
SIC:
NAICS: 238170/Siding Contractors
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/04/2018
Emphasis:
Case Closed: 03/21/2023
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1303027 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $52,100 | $0 | $0 | $0 | $0 | $52,100 |
Current Penalty | $27,100 | $0 | $0 | $0 | $0 | $27,100 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260021 B02 | 05/09/2018 | 06/02/2018 | $0 | $25,000 | $0 | 05/29/2018 | C - Contested | Citation has been deleted. |
2. | 01002 | Serious | 19260416 A01 | 05/09/2018 | 05/13/2018 | $25,000 | $25,000 | $0 | 05/29/2018 | C - Contested | |
3. | 01003 | Serious | 52071100 | 05/09/2018 | 05/13/2018 | $2,100 | $2,100 | $0 | 05/29/2018 | C - Contested |
Investigation Summary
On January 20, 2018, three employees were working from lifts to install the gutters on a three story residential style construction site. The employee was working in a telescoping lift (JLG 660SJ), the employee next to him was working from the basket of a Telehandler (SkyJack SJ643), and the third employee was working from an articulating lift (JLG 450 AJ). The employee in the JLG450 AJ contacted a 7,970 volt power line and electricity flowed through the gutter causing the employee to be electrocuted and the other two employees to be shocked. The power line that was contacted was 26 feet from the building employees were working on. The JLG 450 AJ was 29 feet to the center of the back tire to the building. There was 14 feet between the JLG 450 AJ and the Skyjack SJ 643 and 30 feet between the SJ 643 and the JLG 660 SJ. The overall length of the gutter was 70 feet.
Keywords: Aerial Lift, Construction, Electrocuted, Power Lines
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1289404.015 | 39 | M | Hospitalized injury | Occupation not reported | |
2 | 1289404.015 | 42 | M | Fatality | Occupation not reported |