Inspection Detail
Inspection: 1285758 - Ltv Steel Tubular Division
Inspection Information - Office: Cleveland Area Office
Site Address:
Ltv Steel Tubular Division
Short St
Campbell, OH 44405
Mailing Address:
, , 00000
Union Status: Union
SIC:3312
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/25/1984
Emphasis:
Case Closed: 07/08/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360646152 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 1 | 3 | |||
Initial Penalty | $1,260 | $0 | $0 | $0 | $0 | $1,260 |
Current Penalty | $1,260 | $0 | $0 | $0 | $0 | $1,260 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100304 E01 I | 10/03/1984 | 10/06/1984 | $630 | $630 | $0 | - | ||
2. | 01002A | Serious | 19100304 F01 IV | 10/03/1984 | 10/06/1984 | $630 | $630 | $0 | - | ||
3. | 01002B | Serious | 19100304 F05 V | 10/03/1984 | 10/06/1984 | $0 | $0 | $0 | - | ||
4. | 02001 | Other | 19100305 G01 III | 10/03/1984 | 10/06/1984 | $0 | $0 | $0 | - |
Investigation Summary
AN EMPLOYEE WAS FOUND IN ABOUT 2 FEET OF WATER IN THE BASEMENT OF A HOT MILL. HE HAD A BRUISE ON HIS FOREHEAD, WHICH INDICATED THAT HE MAY HAVE LOST CONSCIOUSNESS AS A RESULT OF THE HEAD INJURY AND SUBSEQUENTLY DROWNED. IT IS ALSO POSSIBLE THAT HIS DROWNING WAS RELATED TO ELECTRIC SHOCK (I. E., HE COULD HAVE LOST CONSCIOUSNESS FROM AN ELECTRIC SHOCK, OR HE COULD HAVE RECEIVED THE HEAD INJURY AS A RESULT OF INVOLUNTARY REACTION FROM AN ELECTRIC SHOCK). AN ELECTRIC PUMP, WHICH HAD ITS WIRING ALTERED, WAS IN THE WATER. ITS AUTOMATIC SWITCH HAD BEEN DISCONNECTED, AND A 5-INCH PIECE OF WIRE HAD BEEN USED TO CONNECT A SUPPLY CONDUCTOR TO THE MOTOR TERMINAL TO WHICH THE WIRE WAS SOLDERED. HEAT ON THE WIRE MELTED THE OIL SEAL ON THE MOTOR ALLOWING OIL TO LEAK FROM THE MOTOR INTO THE CONTROL BOX. THE 120-VOLT ELECTRIC PUMP WAS SUPPLIED BY A 50-FOOT EXTENSION CORD SET THAT HAD THE GROUNDING PRONG MISSING. ADDITIONALLY, THE RECEPTACLE OUTLET WAS NOT A GROUNDING-TYPE OUTLET. THE RECEPTACLE WAS SUPPLIED FROM A BOX THAT CONTAINED A 30-AMPERE FUSE WITH 2 FUSE LINKS CONNECTED TO INCREASE THE FUSE'S CAPACITY TO APPROXIMATELY 60 AMPERES. THE INSULATION ON THE CORD FOR THE ELECTRIC PUMP HAD MELTED WHERE THE UNGROUNDED (BLACK) CONDUCTOR HAD OVERHEATED, AND THE WIRE HAD SEPARATED. THE INSULATION ON THE CONDUCTORS HAD MELTED AND BURNED FROM THE WATER LINE TO WITHIN 6 INCHES OF THE ATTACHMENT PLUG.
Keywords: E GI V, HEAD, OVERCURRENT PROTECT, ELECTRICAL, ELECTRIC PUMP, GROUND FAULT, EQUIPMENT GROUNDING, DROWN, OVERCURRENT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1285758 | Fatality | Asphyxia | Occupation not reported |