Inspection: 1285758 - Ltv Steel Tubular Division

Inspection Information - Office: Cleveland Area Office

 

Inspection Nr: 1285758
Report ID: 0522300
Date Opened: 09/12/1984

Site Address:
Ltv Steel Tubular Division
Short St
Campbell, OH 44405

Mailing Address:
, , 00000

Union Status: Union

SIC:3312

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/25/1984

Emphasis:

Case Closed: 07/08/1986


Related Activity
Type Activity Nr Safety Health
Accident 360646152
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $1,260 $0 $0 $0 $0 $1,260
Current Penalty $1,260 $0 $0 $0 $0 $1,260
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100304 E01 I 10/03/1984 10/06/1984 $630 $630 $0 -  
2. 01002A Serious 19100304 F01 IV 10/03/1984 10/06/1984 $630 $630 $0 -  
3. 01002B Serious 19100304 F05 V 10/03/1984 10/06/1984 $0 $0 $0 -  
4. 02001 Other 19100305 G01 III 10/03/1984 10/06/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 570358
Event: 09/06/1984
DROWNING CAUSED BY HEAD INJURY OR ELECTRIC SHOCK

AN EMPLOYEE WAS FOUND IN ABOUT 2 FEET OF WATER IN THE BASEMENT OF A HOT MILL. HE HAD A BRUISE ON HIS FOREHEAD, WHICH INDICATED THAT HE MAY HAVE LOST CONSCIOUSNESS AS A RESULT OF THE HEAD INJURY AND SUBSEQUENTLY DROWNED. IT IS ALSO POSSIBLE THAT HIS DROWNING WAS RELATED TO ELECTRIC SHOCK (I. E., HE COULD HAVE LOST CONSCIOUSNESS FROM AN ELECTRIC SHOCK, OR HE COULD HAVE RECEIVED THE HEAD INJURY AS A RESULT OF INVOLUNTARY REACTION FROM AN ELECTRIC SHOCK). AN ELECTRIC PUMP, WHICH HAD ITS WIRING ALTERED, WAS IN THE WATER. ITS AUTOMATIC SWITCH HAD BEEN DISCONNECTED, AND A 5-INCH PIECE OF WIRE HAD BEEN USED TO CONNECT A SUPPLY CONDUCTOR TO THE MOTOR TERMINAL TO WHICH THE WIRE WAS SOLDERED. HEAT ON THE WIRE MELTED THE OIL SEAL ON THE MOTOR ALLOWING OIL TO LEAK FROM THE MOTOR INTO THE CONTROL BOX. THE 120-VOLT ELECTRIC PUMP WAS SUPPLIED BY A 50-FOOT EXTENSION CORD SET THAT HAD THE GROUNDING PRONG MISSING. ADDITIONALLY, THE RECEPTACLE OUTLET WAS NOT A GROUNDING-TYPE OUTLET. THE RECEPTACLE WAS SUPPLIED FROM A BOX THAT CONTAINED A 30-AMPERE FUSE WITH 2 FUSE LINKS CONNECTED TO INCREASE THE FUSE'S CAPACITY TO APPROXIMATELY 60 AMPERES. THE INSULATION ON THE CORD FOR THE ELECTRIC PUMP HAD MELTED WHERE THE UNGROUNDED (BLACK) CONDUCTOR HAD OVERHEATED, AND THE WIRE HAD SEPARATED. THE INSULATION ON THE CONDUCTORS HAD MELTED AND BURNED FROM THE WATER LINE TO WITHIN 6 INCHES OF THE ATTACHMENT PLUG.

Keywords: E GI V, HEAD, OVERCURRENT PROTECT, ELECTRICAL, ELECTRIC PUMP, GROUND FAULT, EQUIPMENT GROUNDING, DROWN, OVERCURRENT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1285758 Fatality Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.