Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1283313.015 - Simmonds Precision Products Inc

Inspection Information - Office: Vt Department Of Labor - Vosha

 

Inspection Nr: 1283313.015
Report ID: 0155010
Date Opened: 12/08/2017

Site Address:
Simmonds Precision Products Inc
100 Panton Road
Vergennes, VT 05491

Mailing Address:
100 Panton Road, Vergennes, VT 05491

Union Status: NonUnion

SIC:

NAICS: 336413/Other Aircraft Parts and Auxiliary Equipment Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 12/15/2017

Emphasis: N:Dustexpl

Case Closed: 04/25/2018


Related Activity
Type Activity Nr Safety Health
Referral 1291263 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1 2
Initial Penalty $25,350 $0 $0 $0 $0 $25,350
Current Penalty $0 $0 $0 $7,605 $7,605 $15,210
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Unclass GENERAL DUTY CLAUSE 04/02/2018 04/03/2018 $7,605 $12,675 $0 I - Informal Settlement  
2. 01002 Other 19101200 H03 04/02/2018 05/03/2018 $7,605 $12,675 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 101531.015
Event: 12/08/2017
Employee is hospitalized after aluminum dust collector explo

At 12:00 p.m. on December 8, 2017, Employee #1 was adjusting a new sanding belt onto a horizontal belt sander that was serviced by the dust collector without explosion controls. An ember from the misaligned sanding belt was transported into the dust collection conveyance conduit to the separation cyclone, exposing a dispersed fraction of combustible aluminum dust to a source of ignition. A super-heated percussion wave pushed backwards through the dust collection conveyance ducting from the dust collection separator, and hit the 15 proximally-located employees with super-heated air causing second degree burns and a percussion wave that caused Barotrauma effects to the brain and Eustachian tubes and loss of hearing. Employee #1 was hospitalized for his injuries.

Keywords: Aluminum Dust, Burn, Combustible Dust, Dust Collector, Explosion, Hearing Loss, Heat, Lockout, Struck By

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1283313.015 1 F Non Hospitalized injury Inspectors, testers and graders
2 1283313.015 1 M Non Hospitalized injury Assemblers
3 1283313.015 1 M Non Hospitalized injury Inspectors, testers and graders
4 1283313.015 1 F Non Hospitalized injury Assemblers
5 1283313.015 1 M Non Hospitalized injury Management related occupations, n.e.c.
6 1283313.015 1 F Non Hospitalized injury Miscellaneous material moving equipment operators
7 1283313.015 1 F Non Hospitalized injury Quality Assurance Inspector
8 1283313.015 1 M Non Hospitalized injury Inspectors, testers and graders
9 1283313.015 1 F Non Hospitalized injury
10 1283313.015 1 F Non Hospitalized injury Miscellaneous material moving equipment operators
11 1283313.015 1 M Non Hospitalized injury Assemblers
12 1283313.015 1 F Non Hospitalized injury Assemblers
13 1283313.015 1 M Non Hospitalized injury Compliance Safety And Health Officer (Csho)
14 1283313.015 1 M Hospitalized injury Metal plating machine operators
15 1283313.015 1 F Non Hospitalized injury Assemblers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close