Inspection Detail
Inspection: 1277731.015 - Scott Adams
Inspection Information - Office: San Antonio Area Office
Site Address:
Scott Adams
611 S Crockett Ave
Sonora, TX 76950
Mailing Address:
P.O. Box 815, Junction, TX 76849
Union Status: NonUnion
SIC:
NAICS: 333992/Welding and Soldering Equipment Manufacturing
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/17/2017
Emphasis: P:Fabmetsh, L:Fabmetsh
Case Closed: 05/11/2018
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1285185 |
Investigation Summary
At 4:00 p.m. on November 3, 2017, an employee was planning to cut an enclosed barrel with unknown substance. The employee was applying heat with a cutting torch to the exterior of the barrel. The heat caused an ignition source making the barrel explode. The employee was severely burned and was killed.
Keywords: Chemical, Explosion, Torch
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1277731.015 | 20 | M | Fatality | Welders and cutters |