Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1275237.015 - Prime Touch Services, Inc

Inspection Information - Office: Concord Area Office

 

Inspection Nr: 1275237.015
Report ID: 0111700
Date Opened: 11/02/2017

Site Address:
Prime Touch Services, Inc
162-185 Cannongate Road Building A-2
Nashua, NH 03060

Mailing Address:
16 Tech Circle Suite 102, Natick, MA 01760

Union Status: NonUnion

SIC:

NAICS: 238320/Painting and Wall Covering Contractors


Inspection Type: Fat/Cat

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/02/2017

Emphasis:

Case Closed: 11/08/2018


Related Activity
Type Activity Nr Safety Health
Accident 1280745
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 1 1 2
Initial Penalty $36,216 $0 $0 $0 $0 $36,216
Current Penalty $9,054 $0 $0 $9,054 $0 $18,108
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100332 B01 03/29/2018 04/24/2018 $0 $9,054 $0 04/27/2018 F - Formal Settlement Citation has been deleted.
2. 01002 Serious 19100333 C03 03/29/2018 $9,054 $9,054 $0 04/27/2018 F - Formal Settlement  
3. 01003 Serious 19100333 C03 III A 03/29/2018 $0 $9,054 $0 04/27/2018 F - Formal Settlement Citation has been deleted.
4. 01004 Other 19100333 C07 03/29/2018 $9,054 $9,054 $0 04/27/2018 F - Formal Settlement  

Investigation Summary

Investigation Nr: 100467.015
Event: 11/02/2017
Employee contacts a power line and is killed

At 12:15 p.m. on November 2, 2017, an employee was painting trim boards. The employee was working from an aerial boom lift and had completed the work and was in the process of coming down to the ground when the employee made contact with a 32,000 volt primary power line. The power line was approximately 12 feet away from the building. Contact with the power line was made in the back of the head and the exit wound was through the right hand which was in contact with the boom lift railing. The employee was killed.

Keywords: Aerial Lift, Electrical, Electrocuted, Power Lines

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1275237.015 37 M Fatality Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close