Inspection Detail
Inspection: 1275078.015 - Renewable Energy Systems Americas, Inc
Inspection Information - Office: Oklahoma City Area Office
Site Address:
Renewable Energy Systems Americas, Inc
20278 E 680 Rd
Dover, OK 73734
Mailing Address:
11101 W. 120th Ave,. Suite 400, Broomfield, CO 80021
Union Status: NonUnion
SIC:
NAICS: 237130/Power and Communication Line and Related Structures Construction
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/30/2017
Emphasis:
Case Closed: 10/31/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1278404 | Yes |
Investigation Summary
At 8:00 a.m. on October 25, 2017, Employee #1 and Coworker #1, employed by a company in the renewable energy industry, were working at the construction site for a new project. They were standing in an elevator that failed to move and were attempting to troubleshoot the problem. Employee #1 climbed halfway out through the overhead hatch and was moving onto the ladder when Coworker #1 pushed the elevator's up arrow and the elevator began to move. Employee #1 was crushed between the elevator and the ladder. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for a fractured and punctured right arm. During the subsequent investigation, it was determined that the interlock switch, which should have prevented the elevator from moving with the overhead hatch open, was damaged and not functioning.
Keywords: Arm, Caught Between, Construction, Crushed, Elevator, Equipment Failure, Fracture, Ladder, Puncture, Shaft
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1275078.015 | 25 | M | Hospitalized injury | Construction laborers |
Translate