Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Case Status: CLOSED

Inspection: 1274909.015 - Diversitech Corporation

Inspection Information - Office: Austin

 

Inspection Nr: 1274909.015
Report ID: 0625400
Open Date: 11/02/2017

Site Address:
Diversitech Corporation
5974 Ih 10
Columbus, TX 78934

Mailing Address:
5974 Ih 10, Columbus, TX 78934

Union Status: NonUnion

SIC:

NAICS: 332710/Machine Shops


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/02/2017

Emphasis: N:Amputate, L:Gifall

Close Case:11/24/2017


Related Activity
Type Activity Nr Safety Health
Referral 1274427 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 100424.015
Event: 10/14/2017
Employee'S Fingertips Are Amputated On Concrete Mixer Blades

At 12:00 p.m. on October 14, 2017, Employee #1 was cleaning an energized concret e mixer with the cover open. The employee placed his hand on the lip of the open cover, catching his fingers between the mixer blades and the housing of the mix er. The tips of two of Employee #1's fingers were amputated by the mixer blades. The employee was hospitalized for treatment.

Keywords:amputation, caught between, cleaning, concrete mixer, lockout, mixer blade, struck against

Investigated Inspection
# Inspection Age Sex Degree Nature Occupation
1 1274909.015 Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.