Inspection Detail
Inspection: 127368140 - Temp-Distribution Of Maryland, Inc.
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
Temp-Distribution Of Maryland, Inc.
8200 Stayton Drive
Jessup, MD 20794
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:4225
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/05/1996
Emphasis:
Case Closed: 06/05/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361542046 | ||
| Inspection | 3035797 |
Investigation Summary
Employee #1 had just changed the propane tank on TCM forklift #7, serial #A48807007. He was in the seat directly in front of the propane tank when he started up the lift truck. The propane tank ignited and Employee #1 sustained burns to his face and body. He later stated that the hose attachment to the propane tank was not tight; this was determined after the fire was extinguished.
Keywords: BURN, IND TRK OPERATOR, FLAMMABLE LIQUID, WORK RULES, FIRE, HOSE, INDUSTRIAL TRUCK, PROPANE, FACE, TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 127368140 | Hospitalized injury | Burn/Scald(Heat) | Industrial truck and tractor equipment operators |
Translate