Inspection Detail
Inspection: 127295657 - Four Seasons Repair
Inspection Information - Office: Miosha Construction Safety & Health Division
Site Address:
Four Seasons Repair
9133 Shell-Way
Rapid City, MI 49676
Mailing Address:
4962 N Hickey Creek, Roscommon, MI 48653
Union Status: NonUnion
SIC:1743
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/21/1999
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 07/14/2005
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $250 | $0 | $0 | $100 | $0 | $350 |
Current Penalty | $250 | $0 | $0 | $100 | $0 | $350 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260059 E01 | 05/25/1999 | 05/28/1999 | $250 | $250 | $0 | - | ||
2. | 02001 | Other | 4082234901 | 09/22/1999 | 09/27/1999 | $100 | $100 | $0 | - |
Investigation Summary
Employee #1 was part of a two man crew working at a house removing linoleum tile. The room that crew was working in did not have heat so they brought a heater and a fan to warm up the area. They were using acetone on the tile when an explosion occurred. Employee #1 suffered burns to his body and was hospitalized.
Keywords: HEAT, FAN, HEATER, CONSTRUCTION, ACETONE, EXPLOSION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 127295657 | Hospitalized injury | Burn/Scald(Heat) | Construction laborers |