Inspection Detail
Inspection: 1272153.015 - Therm-Tech Of Waukesha, Inc.
Inspection Information - Office: Milwaukee Area Office
Site Address:
Therm-Tech Of Waukesha, Inc.
301 Travis Lane
Waukesha, WI 53189
Mailing Address:
301 Travis Lane, Waukesha, WI 53189
Union Status: NonUnion
SIC:
NAICS: 332811/Metal Heat Treating
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 10/23/2017
Emphasis:
Case Closed: 12/11/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1274128 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $11,408 | $0 | $0 | $0 | $0 | $11,408 |
| Current Penalty | $7,415 | $0 | $0 | $0 | $0 | $7,415 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100132 A | 10/27/2017 | 11/22/2017 | $7,415 | $11,408 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19101200 G02 | 10/27/2017 | 12/15/2017 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 12:15 p.m. on October 15, 2017, Employee #1 was restarting the heat treat furnace, using an 88 inch wand. Combustible Endo gas had accumulated and was ignited when the employee restarted the furnace. Employee #1 sustained second degree burns to his arms and was hospitalized.
Keywords: Arm, Burn, Furnace, Gas
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1272153.015 | 46 | M | Hospitalized injury | Heat treating equipment operators |