Powered by GoogleTranslate

Inspection Detail

Inspection: 127196327 - House Moving By Vanduinen

Inspection Information - Office: Miosha Construction Safety & Health Division

 

Inspection Nr: 127196327
Report ID: 0552651
Date Opened: 12/06/2002

Site Address:
House Moving By Vanduinen
M-55
Prudenville, MI 48651

Mailing Address:
P.O. Box 395, Houghton Lake, MI 48625

Union Status: NonUnion

SIC:1541

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/28/2003

Planning Guide: Safety-Construction

Emphasis: S:Construction Fatal

Case Closed: 06/11/2003


Related Activity
Type Activity Nr Safety Health
Accident 101402212
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 2 1 3
Initial Penalty $1,125 $0 $0 $0 $0 $1,125
Current Penalty $525 $0 $0 $0 $0 $525
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 4084011402 04/09/2003 04/14/2003 $263 $375 $0 I - Informal Settlement  
2. 01002 Serious 4084011504 04/09/2003 04/14/2003 $263 $375 $0 I - Informal Settlement  
3. 01003 Other 4082213901 04/09/2003 04/14/2003 $0 $375 $0 A - Amendment  

Investigation Summary

Investigation Nr: 201406717
Event: 12/05/2002
One killed, one shocked when antennae strikes power line

On December 5, 2002, Employees #1 and #2 and coworkers were moving a 106 ft long by 23 ft wide metal building. The path of travel took it under a 14,400-volt power line. At a meeting prior to the move, the employees were directed to stay away from the structure while it was passing under the power lines. During the move, Employees #1 and #2 and several coworkers were inside the building in an attempt to steer the trailer when an antenna on the structure struck the power lines. Employee #1 was electrocuted; Employee #2 received an electric shock, sustaining injuries that required hospitalization.

Keywords: STRUCTURE MOVING, CLEARANCE, OVERHEAD POWER LINE, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, METAL POLE, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 127196327 Fatality Electric Shock Construction laborers
2 127196327 Hospitalized injury Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close