Powered by GoogleTranslate

Inspection Detail

Inspection: 127168862 - Miedema Metal Bldg Systems Inc

Inspection Information - Office: Miosha Construction Safety & Health Division

 

Inspection Nr: 127168862
Report ID: 0552651
Date Opened: 09/18/2001

Site Address:
Miedema Metal Bldg Systems Inc
5375 Edgeway Dr
Allendale, MI 49401

Mailing Address:
3620 Highland Dr, Hudsonville, MI 49426

Union Status: NonUnion

SIC:1541

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/10/2001

Planning Guide: Safety-Construction

Emphasis: S:Construction

Case Closed: 11/27/2001


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $1,500 $0 $0 $0 $0 $1,500
Current Penalty $750 $0 $0 $0 $0 $750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 4084011402 10/24/2001 10/29/2001 $750 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201405438
Event: 08/24/2001
Employee injured after falling from metal deck

On August 24, 2001, an employee of Miedema Metal Building System Inc. was installing roof on a preengineered metal building when he fell 25 ft to the ground because of dew on metal deck surface. He was hospitalized for fractures.

Keywords: FRACTURE, METAL DECKING, FALL, FALL PROTECTION, SLIPPERY SURFACE, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 127168862 Hospitalized injury Fracture Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close