Inspection Detail
Inspection: 127082337 - Day Costruction Co. Inc.
Inspection Information - Office: Miosha Construction Safety & Health Division
Site Address:
Day Costruction Co. Inc.
Spencer & Forbes St
Lansing, MI 48915
Mailing Address:
7760 N. Sheridan Rd., Edmore, MI 48829
Union Status: Union
SIC:1799
NAICS: 0
Inspection Type: Planned
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/30/2000
Planning Guide: Safety-Construction
Emphasis: S:Construction
Case Closed: 10/11/2000
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $3,050 | $0 | $0 | $0 | $0 | $3,050 |
Current Penalty | $1,525 | $0 | $0 | $0 | $0 | $1,525 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 4084011402 B | 09/12/2000 | 09/15/2000 | $525 | $1,050 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 4084061701 | 09/12/2000 | 09/15/2000 | $1,000 | $2,000 | $0 | I - Informal Settlement |
Investigation Summary
An employee was using a boring machine to install a two inch gas line. The bore hit an energized underground 13.2 KV electrical duct causing property damage.
Keywords: DUCT, ELECTRICAL, GAS, BORING MACHINE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 127082337 | Occupation not reported |