Inspection Detail
Inspection: 127036937 - Western Waterproofing Co
Inspection Information - Office: Miosha Construction Safety & Health Division
Site Address:
Western Waterproofing Co
26555 Evergreen Rd
Southfield, MI 48034
Mailing Address:
13800 Eckles, Livonia, MI 48150
Union Status: Union
SIC:1799
NAICS: 0
Inspection Type: Planned
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/31/2000
Planning Guide: Safety-Construction
Emphasis: S:Construction
Case Closed: 06/09/2002
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 15 | 3 | 18 | |||
Current Violations | 7 | 5 | 12 | |||
Initial Penalty | $21,800 | $0 | $0 | $0 | $0 | $21,800 |
Current Penalty | $6,860 | $0 | $0 | $0 | $0 | $6,860 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 4084011401 | 10/26/2000 | 10/31/2000 | $0 | $1,400 | $0 | 12/05/2000 | F - Formal Settlement | |
2. | 01002 | Serious | 4084120901 A | 10/26/2000 | 10/31/2000 | $0 | $2,000 | $0 | 12/05/2000 | F - Formal Settlement | Citation has been deleted. |
3. | 01003 | Serious | 4084120902 A | 10/26/2000 | 10/31/2000 | $1,400 | $2,000 | $0 | 12/05/2000 | F - Formal Settlement | |
4. | 01004 | Other | 4084121307 | 10/26/2000 | 10/31/2000 | $0 | $1,000 | $0 | 12/05/2000 | F - Formal Settlement | |
5. | 01005 | Serious | 4084122901 | 10/26/2000 | 10/31/2000 | $980 | $1,400 | $0 | 12/05/2000 | F - Formal Settlement | |
6. | 01006 | Serious | 4084122908 | 10/26/2000 | 10/31/2000 | $980 | $1,400 | $0 | 12/05/2000 | F - Formal Settlement | |
7. | 01007 | Serious | 4084122914 | 10/26/2000 | 10/31/2000 | $560 | $800 | $0 | 12/05/2000 | F - Formal Settlement | |
8. | 01008 | Serious | 4084126104 A | 10/26/2000 | 10/31/2000 | $980 | $1,400 | $0 | 12/05/2000 | F - Formal Settlement | |
9. | 01009 | Other | 408417190117 | 10/26/2000 | 10/31/2000 | $0 | $1,400 | $0 | 12/05/2000 | F - Formal Settlement | |
10. | 01010 | Serious | 4084172301 | 10/26/2000 | 10/31/2000 | $560 | $800 | $0 | 12/05/2000 | F - Formal Settlement | |
11. | 01011 | Serious | 4084172508 A | 10/26/2000 | 10/31/2000 | $1,400 | $2,000 | $0 | 12/05/2000 | F - Formal Settlement | |
12. | 01012 | Other | 4084172508 D | 10/26/2000 | 10/31/2000 | $0 | $1,400 | $0 | 12/05/2000 | F - Formal Settlement | |
13. | 01013 | Serious | 4084172511 | 10/26/2000 | 10/31/2000 | $0 | $1,400 | $0 | 12/05/2000 | F - Formal Settlement | Citation has been deleted. |
14. | 01014 | Serious | 4084196701 | 10/26/2000 | 10/31/2000 | $0 | $2,000 | $0 | 12/05/2000 | F - Formal Settlement | Citation has been deleted. |
15. | 01015 | Serious | 40801011 A | 10/26/2000 | 10/31/2000 | $0 | $1,400 | $0 | 12/05/2000 | F - Formal Settlement | Citation has been deleted. |
16. | 02001 | Other | 4084126102 | 10/26/2000 | 10/31/2000 | $0 | $0 | $0 | 12/05/2000 | F - Formal Settlement | |
17. | 02002 | Other | 4084193804 | 10/26/2000 | 10/31/2000 | $0 | $0 | $0 | 12/05/2000 | F - Formal Settlement | Citation has been deleted. |
18. | 02003 | Other | 4082211103 | 10/26/2000 | 10/31/2000 | $0 | $0 | $0 | 12/05/2000 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
Employee #1 was working from a swing-stage scaffold when one of the suspension ropes broke. He fell approximately 60 ft before his slack lifeline took hold of his safety harness and stopped his fall. He sustained rope burns on his arms from the lifeline.
Keywords: BURN, LIFELINE, WORK RULES, CONSTRUCTION, EQUIPMENT FAILURE, SCAFFOLD COLLAPSE, TWO PT SUSP SCAFFOLD, FALL, ARM, SUSPENSION STRAND
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 127036937 | Non Hospitalized injury | Bruise/Contus/Abras | Construction laborers |