Powered by GoogleTranslate

Inspection Detail

Inspection: 127025948 - Tci Of Michigan Inc

Inspection Information - Office: Miosha Construction Safety & Health Division

 

Inspection Nr: 127025948
Report ID: 0552651
Date Opened: 07/15/1999

Site Address:
Tci Of Michigan Inc
745 Lansing Ave
Jackson, MI 48202

Mailing Address:
2000 Cooper, Jackson, MI 49202

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/10/1999

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 01/19/2000


Related Activity
Type Activity Nr Safety Health
Accident 101401149
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 1 8
Current Violations 7 1 8
Initial Penalty $9,600 $0 $0 $0 $0 $9,600
Current Penalty $9,600 $0 $0 $0 $0 $9,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100268 C 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment  
2. 01002 Serious 19100268 F01 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment  
3. 01003 Serious 19100268 F05 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment  
4. 01004 Serious 19100268 M01 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment  
5. 01005 Serious 19100268 M03 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment  
6. 01006 Serious 19100268 M04 09/15/1999 09/20/1999 $1,500 $1,500 $0 A - Amendment  
7. 01007 Serious 4084320911 09/15/1999 09/20/1999 $600 $600 $0 A - Amendment  
8. 02001 Other 4084320506 09/15/1999 09/20/1999 $0 $0 $0 A - Amendment  

Investigation Summary

Investigation Nr: 201403151
Event: 07/14/1999
Electric Shock - Ground Fault in Pole Ground

An employee was attaching a bonding jumper for a new communication cable strand. He was electrocuted when he contacted an energized ground on a utility pole.

Keywords: ELECTRICAL, TELECOM WORK, COMMUNICATION CABLE, E TC, ELECTROCUTED, GROUND FAULT, STRAND INSTALLATION, SYSTEM GROUNDING, UTILITY POLE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 127025948 Fatality Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close