Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1268902.015 - California Dairies

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 1268902.015
Report ID: 0950625
Date Opened: 10/09/2017

Site Address:
California Dairies
11894 Ave 120
Tipton, CA 93272

Mailing Address:
755 "F" Street, Fresno, CA 93706

Union Status: NonUnion

SIC:

NAICS: 311514/ Dry, Condensed, and Evaporated Dairy Product Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/27/2018

Emphasis:

Case Closed: 08/29/2018


Related Activity
Type Activity Nr Safety Health
Accident 1263992
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 2 2
Initial Penalty $18,000 $0 $0 $1,000 $0 $19,000
Current Penalty $0 $0 $0 $1,620 $0 $1,620
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3314(G)(2)(A) 03/02/2018 04/06/2018 $810 $1,000 $0 03/15/2018 O - Administrative Law Judge Order  
2. 02001 Other 3314(C) 03/02/2018 03/14/2018 $810 $18,000 $0 03/15/2018 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 103244.015
Event: 09/03/2017
Employee is sprayed by hot liquid and receives second degree

At 5:00 p.m. on September 3, 2017, Employee #1 and Employee #2 were attempting to repair the tri-clover fitting between the supply line for the CIP to the flow panel on a raw milk silo because the fitting had developed a leak. Employee #1 went to the control room to shut down the silo in preparation to repair the leak. When he came back to the flow panel of the silo, Employee #1 and Employee #2 loosened the clamp on the flow panel. No liquid came out. The connection from the flow panel was then removed. Employee #2 then picked up the line and gasket when water suddenly came on from the silo flow panel port. Employee #2 was hit with 160 degree CIP solution, sustaining second degree burns to his left arm, thighs, groin and genitals.

Keywords: Burn, Hot Water

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1268902.015 29 M Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.