Inspection Detail
Inspection: 1268754 - Trizzino Construction Co.
Inspection Information - Office: Chicago South Area Office
Site Address:
Trizzino Construction Co.
918 Caroline Joliet Twp
Joliet, IL 60436
Mailing Address:
309 East Cass Street, Joliet, IL 60436
Union Status: NonUnion
SIC:1771
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/22/1986
Emphasis:
Case Closed: 04/11/1990
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360545800 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $300 | $0 | $0 | $0 | $0 | $300 |
| Current Penalty | $300 | $0 | $0 | $0 | $0 | $300 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19260400 C01 | 06/28/1985 | 07/01/1985 | $300 | $300 | $0 | - | ||
| 2. | 01001B | Serious | 19260021 B02 | 06/28/1985 | 07/01/1985 | $0 | $0 | $0 | - |
Investigation Summary
AN EMPLOYEE WAS USING A BULL FLOAT (PRESUMABLY TO SMOOTH CONCRETE). THE HANDLE OF THE BULL FLOAT CONTACTED AN OVERHEAD POWER LINE, AND THE EMPLOYEE WAS ELECTROCUTED.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E C, EXTENSION HANDLE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1268754 | Fatality | Electric Shock | Occupation not reported |
Translate