Inspection Detail
Inspection: 126791110 - Aztec Well Servicing Co.
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
Aztec Well Servicing Co.
Chapita Wells Unit 547-2f
Uintah County, UT 84078
Mailing Address:
P O Box 100, Aztec, NM 87410
Union Status: NonUnion
SIC:1311
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/03/1998
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/01/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362649519 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $1,000 | $0 | $0 | $0 | $0 | $1,000 |
| Current Penalty | $1,000 | $0 | $0 | $0 | $0 | $1,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 20001 I02 6 | 08/12/1998 | 08/18/1998 | $1,000 | $1,000 | $0 | - | ||
| 2. | 01001B | Serious | 20009 A02 | 08/12/1998 | 08/18/1998 | $0 | $0 | $0 | - | ||
| 3. | 01001C | Serious | 20009 C06 | 08/12/1998 | 08/18/1998 | $0 | $0 | $0 | - | ||
| 4. | 01001D | Serious | 20009 E01 | 08/12/1998 | 08/18/1998 | $0 | $0 | $0 | - | ||
| 5. | 01001E | Serious | 20009 E02 | 08/12/1998 | 08/18/1998 | $0 | $0 | $0 | - | ||
| 6. | 01001F | Serious | 20009 G01 D | 08/12/1998 | 08/18/1998 | $0 | $0 | $0 | - | ||
| 7. | 02001 | Other | 20003 I04 B | 08/12/1998 | 09/29/1998 | $0 | $0 | $0 | - | ||
| 8. | 02002 | Other | 19101030 F02 IV | 08/12/1998 | 09/29/1998 | $0 | $0 | $0 | - |
Investigation Summary
An employee was helping to set up a gas- and oil-well drilling rig. While he was standing in mud, he grabbed a 240-volt electric cord that had a break in its insulation. He contacted an energized conductor through his wet work gloves and was electrocuted.
Keywords: E GI V, ELEC INSULATION, ELECTRICAL, ELECTROCUTED, ELECTRIC CORD, WATER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126791110 | Fatality | Electric Shock | Production helpers |