Inspection: 126765403 - Kelatron Inc.

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 126765403
Report ID: 0854910
Date Opened: 12/12/1996

Site Address:
Kelatron Inc.
3660 Lincoln Avenue
Ogden, UT 84405

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2833

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/03/1997

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 12/13/1997


Related Activity
Type Activity Nr Safety Health
Accident 361535511
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 3 8
Current Violations 5 3 8
Initial Penalty $9,150 $0 $0 $900 $0 $10,050
Current Penalty $6,500 $0 $0 $800 $0 $7,300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 10200130101 01/28/1997 02/01/1997 $1,300 $1,800 $0 A - Amendment  
2. 01001B Serious 102001402 01/28/1997 02/05/1997 $0 $0 $0 -  
3. 01002A Serious 19100134 A02 01/28/1997 03/02/1997 $1,300 $1,800 $0 A - Amendment  
4. 01002B Serious 19100134 B05 01/28/1997 02/01/1997 $0 $0 $0 -  
5. 01002C Serious 19100134 B10 01/28/1997 02/15/1997 $0 $0 $0 -  
6. 01002D Serious 19100134 B11 01/28/1997 02/01/1997 $0 $0 $0 -  
7. 01002E Serious 19100134 E04 01/28/1997 02/01/1997 $0 $0 $0 -  
8. 01002F Serious 19100134 E05 01/28/1997 02/15/1997 $0 $0 $0 -  
9. 01003 Serious 19100147 C01 01/28/1997 02/15/1997 $1,300 $1,800 $0 A - Amendment  
10. 01004 Serious 19100212 A01 01/28/1997 02/01/1997 $1,300 $1,950 $0 A - Amendment  
11. 01005A Serious 19101000 A02 01/28/1997 02/01/1997 $1,300 $1,800 $0 A - Amendment  
12. 01005B Serious 19101000 E 01/28/1997 06/10/1997 $0 $0 $0 -  
13. 02001 Other 19100101 B 01/28/1997 03/02/1997 $250 $300 $0 A - Amendment  
14. 02002 Other 19100303 H03 I 01/28/1997 03/02/1997 $250 $300 $0 A - Amendment  
15. 02003 Other 19101200 E01 01/28/1997 03/02/1997 $300 $300 $0 -  

Investigation Summary

Investigation Nr: 171054760
Event: 12/11/1996
Employee injured in lab explosion

At approximately 5:55 p.m. on December 11, 1996, Employee #1, a chemist with Kelatron, Inc., was using a Perkin-Elmer atomic absorption spectrometer, model 603, to run a boron assay in his company's quality control laboratory. During the course of this process, a glass waste bottle exploded. Employee #1 was struck by flying glass fragments, suffering minor cuts and burns to his lower legs. He also sustained facial cuts from an overhead light that fell as a result of the explosion, and a bruised eardrum and hearing loss from the explosion itself. Apparently, the drain tube trap was not properly filled with water, which allowed acetylene gas to flow and accumulate in the waste bottle. The source of ignition was most likely static.

Keywords: STATIC ELECTRICITY, ACETYLENE, EAR, EXPLOSION, HEARING LOSS, LACERATION, STRUCK BY, CHEMICAL VAPOR, FLYING OBJECT, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126765403 Non Hospitalized injury Burn/Scald(Heat) Chemists, except biochemists
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.