Powered by GoogleTranslate

Inspection Detail

Inspection: 126709880 - Westwood Industries Inc

Inspection Information - Office: Or-E-Salem 1054100

 

Inspection Nr: 126709880
Report ID: 1054118
Date Opened: 04/16/1998

Site Address:
Westwood Industries Inc
190 West 10th St
Junction City, OR 97448

Mailing Address:
Po Box 2711, Eugene, OR 97402

Union Status: NonUnion

SIC:2434

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/10/1998

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/10/2001


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 2 2
Initial Penalty $12,000 $0 $0 $0 $0 $12,000
Current Penalty $2,500 $0 $0 $0 $0 $2,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 701076001 B D 07/29/1998 04/16/1998 $0 $7,000 $0 08/11/1998 F - Formal Settlement Citation has been deleted.
2. 01002 Serious 701076001 A 07/29/1998 04/16/1998 $0 $1,250 $0 08/11/1998 F - Formal Settlement Citation has been deleted.
3. 01003 Serious 701076003 C A 07/29/1998 04/16/1998 $0 $1,250 $0 08/11/1998 F - Formal Settlement Citation has been deleted.
4. 01004 Serious 19100147 C04 I 07/29/1998 04/16/1998 $1,250 $1,250 $0 08/11/1998 F - Formal Settlement  
5. 01005 Serious 19100147 C07 I 07/29/1998 04/16/1998 $1,250 $1,250 $0 08/11/1998 F - Formal Settlement  

Investigation Summary

Investigation Nr: 170805212
Event: 04/13/1998
Employee's fingers amputated in rotating saw blade

Just before 12 noon on April 13, 1998, Employee #1, a Dimter saw operator, was trying to unclog sawdust and wood chips from the exhaust vent under the saw blade. The saw was located in a metal enclosure, and access to the vent was through a safety-interlocked metal door with a three-minute delay timer to insure that the saw blade has stopped rotating before an operator can access the vent. Employee #1 was reaching into the exhaust vent area when her left hand contacted the rotating saw blade, amputating three fingers. A year earlier the safety interlock switch had been disabled by removing two bolts on the metal gate; this allowed the operator to open the door while the saw blade was still rotating.

Keywords: ROTATING PARTS, AMPUTATED, FINGER, VENTING, WORK RULES, INTERLOCK, SAW, CLOGGED, BLADE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126709880 Hospitalized injury Amputation Sawing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.