Inspection Detail
Inspection: 126687672 - Monaco Coach Corporation
Inspection Information - Office: Eugene
Site Address:
Monaco Coach Corporation
91320 Coburg Industrial Way
Coburg, OR 97408
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3711
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/20/1998
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 05/02/2000
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 701076001 A | 01/21/1998 | 03/08/1998 | $2,500 | $5,000 | $0 | 02/05/1998 | L - State Settlement |
Investigation Summary
On July 30, 1997, Employee #1, of Monaco Coach Corporation, was replacing a fuel gauge sending unit on a partially filled propane tank of a motor coach. Employee #2 was simultaneously working on an adjacent coach. Employee #1 inadvertently removed screws from a plate on the tank, creating a propane leak. The fuel was apparently ignited by a battery operated screwdriver. Employees #1 and #2 sustained serious burns in the ensuing fire.
Keywords: BURN, LEAK, PORTABLE POWER TOOL, AUTOMOTIVE REPAIR, FLAMMABLE LIQUID, FLAMMABLE VAPORS, WORK RULES, FIRE, PROPANE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 126687672 | Hospitalized injury | Burn/Scald(Heat) | Electrical power installers and repairers | ||
2 | 126687672 | Hospitalized injury | Burn/Scald(Heat) | Construction trades, n.e.c. |