Powered by GoogleTranslate

Inspection Detail

Inspection: 126637826 - Branson'S Auto Repair

Inspection Information - Office: Va-E-Richmond (Regional Office) - Safety 0355111

 

Inspection Nr: 126637826
Report ID: 0355111
Date Opened: 03/07/1996

Site Address:
Branson'S Auto Repair
Intersection Of Rts. 621 & 202
Mt Holly, VA 22524

Mailing Address:
Route 1, Box 537, Montross, VA 22520

Union Status: NonUnion

SIC:7539

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/08/1996

Emphasis:

Case Closed: 07/07/2010


Related Activity
Type Activity Nr Safety Health
Accident 360300404
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $14,000 $0 $0 $0 $0 $14,000
Current Penalty $14,000 $0 $0 $0 $0 $14,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100036 B08 07/26/1996 07/30/1996 $7,000 $7,000 $0 07/26/1996 Y - State Decision  
2. 01001B Serious 19100037 I 07/26/1996 07/30/1996 $0 $0 $0 07/26/1996 Y - State Decision  
3. 01002 Serious 19100106 G06 IV 07/26/1996 07/30/1996 $7,000 $7,000 $0 07/26/1996 Y - State Decision  

Investigation Summary

Investigation Nr: 951061
Event: 03/07/1996
Employee killed when gasoline vapors ignite

At approximately 10:00 a.m. on March 7, 1995, Employee #1 was sitting in the front seat of a van while her employer replaced the fuel pump in the gasoline tank at the rear. The employer had jacked the gasoline tank down, replaced the fuel pump, and was jacking the tank back into place when the flammable gasoline vapors were ignited by an lpg heater located at the left front of the van. This resulted in a fire and several explosions. Employee #1 was trapped inside the van and died in the fire.

Keywords: AUTOMOTIVE REPAIR, FLAMMABLE VAPORS, HEATER, WORK RULES, FIRE, EXPLOSION, LP GAS, GASOLINE, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126637826 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close