Inspection Detail
Inspection: 1265207.015 - Novus Polaris, Inc.
Inspection Information - Office: Corpus Christi Area Office
Site Address:
Novus Polaris, Inc.
3108 N. Sugar Rd
Pharr, TX 78577
Mailing Address:
323 West Expressway 83, Pharr, TX 78577
Union Status: NonUnion
SIC:
NAICS: 453998/All Other Miscellaneous Store Retailers (except Tobacco Stores)
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/20/2017
Emphasis:
Case Closed: 02/22/2018
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1264407 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $5,543 | $0 | $0 | $0 | $0 | $5,543 |
Current Penalty | $3,326 | $0 | $0 | $0 | $0 | $3,326 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100305 B01 II | 02/01/2018 | 02/13/2018 | $998 | $1,663 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100333 B02 II B | 02/01/2018 | 02/13/2018 | $2,328 | $3,880 | $0 | I - Informal Settlement |
Investigation Summary
At 3:30 p.m. on September 15, 2017, an employee was using a drill to attach a metal door to an electrical panel box using screws. A screw contacted a live wire and caused an arc flash. The employee sustained an electric shock.
Keywords: Electrical, Portable Power Tool, Protective Clothing
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1265207.015 | 36 | M | Hospitalized injury | Operations & systems researchers and analysts |