Inspection Detail
Inspection: 126490366 - Bob Jones Univ. Dba Pleasent Pasture Farms
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Bob Jones Univ. Dba Pleasent Pasture Farms
501 Coachman Drive
Fountain Inn, SC 29644
Mailing Address:
1700 Wade Hampton Blvd, Greenville, SC 29614
Union Status: NonUnion
SIC:8221
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/18/1997
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/18/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362627176 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,875 | $0 | $0 | $0 | $0 | $1,875 |
| Current Penalty | $750 | $0 | $0 | $0 | $0 | $750 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 10012 A | 03/14/1997 | 03/19/1997 | $750 | $1,875 | $0 | I - Informal Settlement |
Investigation Summary
Two employees were cleaning out aluminum irrigation pipes. This was one of their normal job duties. A 7200-volt overhead power line was located 8.4 meters above the ground directly over the employees. One of the employees brought a 9.3-meter-long, 178-millimeter-diameter metal pipe into contact with the power line and was electrocuted.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E GI IC, METAL PIPE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126490366 | Fatality | Electric Shock | Managers, farms, except horticultural |