Inspection Detail
Inspection: 126467273 - Performance Friction
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Performance Friction
83 Carbon Metallic Dr.
Clover, SC 29710
Mailing Address:
P O Box 819, Clover, SC 29710
Union Status: NonUnion
SIC:3292
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/02/1996
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/13/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362629537 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $6,375 | $0 | $0 | $0 | $0 | $6,375 |
| Current Penalty | $2,550 | $0 | $0 | $0 | $0 | $2,550 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100332 B01 | 07/24/1996 | 08/26/1996 | $1,700 | $4,250 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19100147 C07 I | 07/24/1996 | 08/26/1996 | $0 | $0 | $0 | I - Informal Settlement | ||
| 3. | 01002A | Serious | 19100333 B02 | 07/24/1996 | 07/29/1996 | $850 | $2,125 | $0 | I - Informal Settlement | ||
| 4. | 01002B | Serious | 19100147 F03 II | 07/24/1996 | 07/29/1996 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
Two employees of a high-performance brake manufacturer were removing an attachment plug from a press. One employee was at ground level, and the other employee was up on a stationary work platform at the plug disconnect for the press. The plug was attached to a busbar. The employee on the platform pulled the 480-volt, three-phase disconnect and locked it out. The employee on the ground checked the phase-to-ground and phase-to-phase voltage on the conductors and said that the conductors were deenergized. As the employee on the platform removed the first phase conductor, he received an electric shock. The busbar was still energized. The employee sustained second- and third-degree burns to his right hand and wrist and was hospitalized for his injuries.
Keywords: BURN, E GI IV, ELECTRICAL, ELECTRICIAN, BUSBAR, ELECTRICAL WORK, LOCKOUT, ELECTRIC SHOCK, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126467273 | Hospitalized injury | Electric Shock | Misc. electrical & electronic equipment repairers |
Translate