Powered by GoogleTranslate

Inspection Detail

Inspection: 126197631 - Republic Master Chefs

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 126197631
Report ID: 0950641
Date Opened: 08/31/2005

Site Address:
Republic Master Chefs
1664 W. Washington Blvd.
Los Angeles, CA 90007

Mailing Address:
1667 W. Washington Blvd., Los Angeles, CA 90007

Union Status: Union

SIC:7211

NAICS: 812320/Drycleaning and Laundry Services (except Coin-Operated)


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/31/2005

Emphasis:

Case Closed: 07/03/2006


Related Activity
Type Activity Nr Safety Health
Accident 362585481
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $6,750 $0 $0 $5,000 $0 $11,750
Current Penalty $6,750 $0 $0 $5,000 $0 $11,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 01/04/2006 01/22/2006 $5,000 $5,000 $0 -  
2. 02001 Serious 3329 A 01/04/2006 01/09/2006 $6,750 $6,750 $0 -  

Investigation Summary

Investigation Nr: 201167186
Event: 07/19/2005
Employee Is Scalded by Hot Water from Washing Machine

On July 19, 2005, Employee #1, a supervising engineer, replaced a hose on a washing machine, Number 1. Employee #1 is responsible for equipment maintenance and making and scheduling repairs as necessary throughout the facility. He disconnected the plumbed waste line of Washer Number1 and installed a new line that consisted of a 2-in. diameter flexible hose connected to a 2-in. diameter steel pipe that was threaded to a stainless steel T-connector and a shut off valve. The end of the flexible hose was then placed between the steel plates of the wastewater trough in the floor adjacent the washer to drain into the wastewater treatment system. The hose type is an Alfagomma hard wall marine exhaust, Model T-600 4+4 SP Plus Marine Exhaust-Fuel S and D 2.2. The hose is rated for temperatures of minus 22 to 212 degrees and is designed for marine wet exhaust. The end of the flexible hose attached to the washing machine for draining whipped loose from the floor drain and sprayed Employee #1 with the hot water. The water pressure exerting on the flexible hose caused the end to pull out of the trough. The end was not secured, supported or maintained to prevent it from coming loose, as required. The employee was scalded and suffered second and third degree burns on his lower trunk and lower extremities of his body and was hospitalized.

Keywords: SCALP, HOSE, HIGH PRESSURE, STRUCK BY, FLYING OBJECT, WASHING MACHINE, HOT WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126197631 Hospitalized injury Burn/Scald(Heat) Supervisors, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.