Powered by GoogleTranslate

Inspection Detail

Inspection: 126196161 - Pbfasteners

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 126196161
Report ID: 0950641
Date Opened: 08/23/2005

Site Address:
Pbfasteners
1700 W. 132nd St.
Gardena, CA 90249

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3721

NAICS: 336411/Aircraft Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/23/2005

Emphasis:

Case Closed: 12/13/2006


Related Activity
Type Activity Nr Safety Health
Accident 101162493
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 2 3 5
Initial Penalty $25,310 $0 $0 $560 $0 $25,870
Current Penalty $5,400 $0 $0 $1,460 $0 $6,860
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23400001 01/13/2006 02/02/2006 $560 $560 $0 02/28/2006 F - Formal Settlement  
2. 02001 Other 4002 A 01/13/2006 02/02/2006 $450 $6,750 $0 02/28/2006 F - Formal Settlement  
3. 03001 Serious 4070 A 01/13/2006 02/02/2006 $2,700 $6,750 $0 02/28/2006 F - Formal Settlement  
4. 04001 Serious 4184 B 01/13/2006 02/02/2006 $2,700 $6,750 $0 02/28/2006 F - Formal Settlement  
5. 05001 Other 23200001 A 01/13/2006 02/02/2006 $450 $5,060 $0 02/28/2006 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201167202
Event: 07/27/2005
Employee's Arm Is Burned in Explosion

At approximately 10:15 a.m. on July 27, 2005, Employee #1, of Pbfasteners, was working in the griding department, straightening out a piece of electrical conduit. The elbow connection sheared off and cut the electrical wires. This caused a short out and an explosion. Employee #1 was hospitalized for treatment of serious first and second degree burns to his inner arms. The factors contributing to this incident included the electrical conduit not being secured to the floor and striking an electrical conduit without deenergizing the power first.

Keywords: BURN, REPAIR, ELECTRICAL, UNSECURED, CONDUIT, ELECTRICAL WORK, EXPLOSION, ARM

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126196161 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close