Powered by GoogleTranslate

Inspection Detail

Inspection: 126193945 - Smmusd Santa Monica High

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 126193945
Report ID: 0950641
Date Opened: 09/14/2007

Site Address:
Smmusd Santa Monica High
601 Pico Bl.
Santa Monica, CA 90405

Mailing Address:
, , 00000

Union Status: Union

SIC:8211

NAICS: 611110/Elementary and Secondary Schools


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/14/2007

Emphasis:

Case Closed: 12/15/2008


Related Activity
Type Activity Nr Safety Health
Accident 101167500
Accident 101167609
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 5 6
Current Violations 1 4 5
Initial Penalty $18,000 $0 $0 $6,780 $0 $24,780
Current Penalty $18,000 $0 $0 $500 $0 $18,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 01/28/2008 02/15/2008 $500 $5,000 $0 03/12/2008 F - Formal Settlement  
2. 01002 Other 3203 A 02/28/2008 03/25/2008 $280 $280 $0 03/12/2008 F - Formal Settlement Citation has been deleted.
3. 01003 Other 3270 B 02/28/2008 03/17/2008 $0 $375 $0 03/12/2008 F - Formal Settlement  
4. 01004 Other 3278 E18 02/28/2008 03/17/2008 $0 $375 $0 03/12/2008 F - Formal Settlement  
5. 01005 Other 3278 E19 02/28/2008 03/17/2008 $0 $750 $0 03/12/2008 F - Formal Settlement  
6. 02001 Serious 3278 E07 02/28/2008 03/17/2008 $18,000 $18,000 $0 03/12/2008 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201169687
Event: 09/06/2007
Employee Is Injured in Fall from Ladder

On September 6, 2007, an employee ascended a wooden ladder that served as access to the roof of the Drake Pool Building. The ladder was positioned under a hatch on the second floor, mezzanine, of the building and had allegedly been in place for over 15-years. The employee opened the hatch in order to allow a film crew onto the roof. The film crew was comprised of various parents of the school's football team members and it was customary to allow various persons onto the roof of the Drake Pool building for better viewing of the athletic events occurring in the athletic field adjacent the building. The hatch cover was padlocked with a master key lock to which all teachers and staff had a key. Prior to the accident, the subject ladder and roof hatch access had reportedly been routinely used by various contractors, faculty, and staff members as well as parents and students to access the roof to not only view the athletic events, but to provide routine maintenance and repair to the solar panels and HVAC equipment that was permanently installed on the roof. The subject ladder was a portable wood ladder was 16-ft 2-inches long and was positioned at an angle. The rails of the ladder rested just below the hatch cover and the feet rested on a smooth concrete surface. The ladder was of the old-school agility ladder type that had previously been wall mounted in the gym and used for stretching. The ladder design was not intended to be used as a portable ladder as both ends of the rails were smooth and rounded. The employee at the top of the ladder and was opening the hatch cover when the ladder slipped causing him to fall to the concrete floor below. The employee suffered numerous fractured bones and various internal injuries. He was hospitalized in intensive care for two-weeks. He returned to work 4-months after the accident and continued ongoing treatment for his injury.

Keywords: FRACTURE, LADDER, FALL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126193945 Hospitalized injury Fracture Physical education teachers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close