Powered by GoogleTranslate

Inspection Detail

Inspection: 126192269 - Richill Steel Construction

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 126192269
Report ID: 0950641
Date Opened: 08/28/2007

Site Address:
Richill Steel Construction
13020 S. Yukon Ave.
Hawthorne, CA 90250

Mailing Address:
12323 Doherty St., Riverside, CA 92503

Union Status: NonUnion

SIC:3499

NAICS: 332999/All Other Miscellaneous Fabricated Metal Product Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/19/2008

Emphasis:

Case Closed: 06/18/2008


Related Activity
Type Activity Nr Safety Health
Accident 101167435
Accident 101167443
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $13,500 $0 $0 $350 $0 $13,850
Current Penalty $13,500 $0 $0 $350 $0 $13,850
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 A 02/19/2008 03/13/2008 $350 $350 $0 -  
2. 02001 Serious 2946 A 02/19/2008 02/15/2008 $13,500 $13,500 $0 -  

Investigation Summary

Investigation Nr: 201169646
Event: 08/21/2007
Employee Is Shocked by Overhead Power Line

At approximately 2:00 p.m. on August 21, 2007, Employee #1 and a coworker were installing a fixed ladder for a cellular satellite station mounted on the roof of an industrial building. The building was 33 ft 5 in. high. An overhead power line was 8 ft 9 in. from the side of the building and 40 ft 5 in. high. Employee #1 was in an elevated basket on a boom. The coworker was on the roof and handed a 2-in. wide, 0.25-in. thick, 14 ft long aluminum strap to Employee #1. The aluminum strap bowed over Employee#1's shoulder and contacted the 16,000 volt overhead line. Employee #1 was shocked. Employee #1 was hospitalized for a month. He suffered burns to 60 percent of his body, brain damage, memory loss, loss of strength, loss of balance, and had both hands amputated.

Keywords: BURN, SHOCK, AMPUTATED, OVERHEAD POWER LINE, FIXED LADDER, ELECTRIC SHOCK, METAL STRIP, HAND, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126192269 Hospitalized injury Electric Shock Sheetmetal duct installers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close