Inspection Detail
Inspection: 126173137 - Pacific Continental Textiles Inc
Inspection Information - Office: Long Beach District Office
Site Address:
Pacific Continental Textiles Inc
2880 E Ana St
Rancho Dominguez, CA 90221
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2211
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/16/1998
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/29/2006
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362540890 | ||
Accident | 362538423 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $225 | $0 | $225 |
Current Penalty | $0 | $0 | $0 | $225 | $0 | $225 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3203 A05 | 10/21/1998 | 10/29/1998 | $225 | $225 | $0 | - |
Investigation Summary
On April 13, 1998, Employee #1 was opening a steam valve during a cold start-up operation after the boiler had been lit. As the employee was opening the valve it blew up. The upper body of the valve detached from the lower portion, releasing steam on Employee #1. The valve and system had been preheated to prevent thermal shock to the boiler system. The system had been in service for five years. Employee #1 was hospitalized for burns.
Keywords: BURN, BOILER, LOCKOUT, STEAM, VALVE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 126173137 | Hospitalized injury | Burn/Scald(Heat) | Machinery maintenance occupations |