Inspection Detail
Inspection: 126171941 - Comparan Electric
Inspection Information - Office: Long Beach District Office
Site Address:
Comparan Electric
4383 Exchange Ave
Vernon, CA 90058
Mailing Address:
12300 E Washington Bl Ste V, Whittier, CA 90606
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/17/1998
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 01/05/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362536096 | ||
| Accident | 362536187 | ||
| Accident | 362540619 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 2 | 5 | |||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $10,500 | $0 | $0 | $335 | $0 | $10,835 |
| Current Penalty | $0 | $0 | $0 | $900 | $0 | $900 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 1509 A | 04/29/1998 | 05/18/1998 | $0 | $110 | $0 | 06/08/1998 | F - Formal Settlement | Citation has been deleted. |
| 2. | 01002 | Other | 1511 B | 04/29/1998 | 05/18/1998 | $0 | $225 | $0 | 06/08/1998 | F - Formal Settlement | Citation has been deleted. |
| 3. | 02001 | Serious | 23200002 A | 04/29/1998 | 05/18/1998 | $0 | $1,750 | $0 | 06/08/1998 | F - Formal Settlement | Citation has been deleted. |
| 4. | 03001 | Other | 3279 | 04/29/1998 | 05/18/1998 | $450 | $5,250 | $0 | 06/08/1998 | J - ALJ Decision | |
| 5. | 04001 | Other | 3279 11 | 04/29/1998 | 05/18/1998 | $450 | $3,500 | $0 | 06/08/1998 | J - ALJ Decision |
Investigation Summary
An electrician was working on a project to demolish an existing installation of electric equipment, including panelboards, conduit, and junction boxes, in a commercial building. Working by himself, the employee borrowed a 6.1-meter-long Keller aluminum extension ladder to reach conduit and junction boxes in a ceiling area. The ladder, which had no feet, slipped, and the employee fell about 6 meters to the floor. He sustained fractures to both legs and ankles and was to have been hospitalized for about 2 months. There were fiberglass ladders at the job site; however, none would have reached the ceiling area. In addition, there was no supervision at the site.
Keywords: LADDER, SLIP, ELECTRICAL WORK, FALL, UNSTABLE POSITION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126171941 | Hospitalized injury | Fracture | Electricians |