Powered by GoogleTranslate

Inspection Detail

Inspection: 126153600 - Environmental Solar Design Inc

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 126153600
Report ID: 0950641
Date Opened: 06/16/2008

Site Address:
Environmental Solar Design Inc
333 S. Wilton Pl.
Los Angeles, CA 90020

Mailing Address:
11237 Magnolia Blvd, N. Hollywood, CA 91601

Union Status: NonUnion

SIC:1799

NAICS: 238990/All Other Specialty Trade Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/20/2008

Planning Guide: Safety-Construction

Emphasis: S:Construction (Cship)

Case Closed: 02/12/2014


Related Activity
Type Activity Nr Safety Health
Accident 102572336
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $12,600 $0 $0 $670 $0 $13,270
Current Penalty $6,500 $0 $0 $255 $0 $6,755
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A04 10/27/2008 10/30/2008 $85 $450 $0 11/03/2008 F - Formal Settlement  
2. 01002 Other 3203 A07 10/27/2008 12/15/2008 $85 $110 $0 11/03/2008 F - Formal Settlement  
3. 01003 Other 3395 E03 10/27/2008 10/30/2008 $85 $110 $0 11/03/2008 F - Formal Settlement  
4. 02001 Serious 2946 A 10/27/2008 10/30/2008 $6,500 $12,600 $0 11/03/2008 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202539128
Event: 06/13/2008
Electric Shock & Fall - Direct Contact with Overhead Line

Three workers were completing the installation of a solar water-heating system on the roof of a three-story apartment building. They were working from a scaffold that was 9.1 meters high. A 4,800-volt overhead power line was located approximately 2 meters away. As one of the workers was raising a 6.1-meter length of unistrut material to the roof, he contacted the power line. He received an electric shock and fell to the concrete. He was hospitalized with electrical burns, multiple fractures, and head injuries. He was removed from life support the day after the accident and died.

Keywords: BURN, OVERHEAD POWER LINE, ROOF, ELECTRICAL, E C, ELECTRIC SHOCK, FALL, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126153600 Fatality Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close