Inspection Detail
Inspection: 126147768 - Alfredo Chavez
Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - South
Site Address:
Alfredo Chavez
4107 W. Gonzales Rd.
Oxnard, CA 93030
Mailing Address:
39 Bowling Rd., Watsonville, CA 95076
Union Status: NonUnion
SIC:0181
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/22/2001
Planning Guide: Safety-Construction
Emphasis: S:Agriculture (Aship)
Case Closed: 09/13/2010
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362493264 | ||
| Accident | 362493272 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $10,800 | $0 | $0 | $85 | $0 | $10,885 |
| Current Penalty | $10,800 | $0 | $0 | $85 | $0 | $10,885 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A | 02/28/2001 | 04/16/2001 | $85 | $85 | $0 | - | ||
| 2. | 02001 | Serious | 2946 A | 02/28/2001 | 03/05/2001 | $10,800 | $10,800 | $0 | - |
Investigation Summary
An employee was on the roof of a greenhouse under construction. A metal frame bar he was holding contacted a 16-kilovolt overhead power line. He received an electric shock and severe burns. He was hospitalized in serious condition with third-degree burns on his hands and feet.
Keywords: BURN, METAL BAR, OVERHEAD POWER LINE, ELECTRICAL, E C, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126147768 | Hospitalized injury | Electric Shock | Carpenters |
Translate