Powered by GoogleTranslate

Inspection Detail

Inspection: 126138783 - Robison Electronics

Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - South

 

Inspection Nr: 126138783
Report ID: 0950645
Date Opened: 09/03/1999

Site Address:
Robison Electronics
3580 Sacramento Dr.
San Luis Obispo, CA 93456

Mailing Address:
P.O. Box 8121, San Luis Obispo, CA 93403

Union Status: NonUnion

SIC:3679

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/08/1999

Emphasis:

Case Closed: 10/26/2000


Related Activity
Type Activity Nr Safety Health
Accident 362499139
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 2 2
Initial Penalty $5,000 $0 $0 $225 $0 $5,225
Current Penalty $0 $0 $0 $1,725 $0 $1,725
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 B02 09/16/1999 10/19/1999 $225 $225 $0 -  
2. 03001 Other 3314 A 09/16/1999 09/21/1999 $1,500 $5,000 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201093317
Event: 08/25/1999
Employee crushed five fingers in power press

At approximately 6:50 a.m. on August 25, 1999, Employee #1 crushed five fingers on his right hand in a power press. He was taken to the hospital. At the time of accident, Employee #1 was operating an 18-ton Gluco-Air Press, Model M18, Press Number 1. This press was heated and made small plastic parts. The point of operation was guarded by a two-hand control and a 6.5-in. plastic shield, and the width of the machine opening. This opening was guarded by a light curtain. Employee #1 was cleaning the top head of the press with his right hand. Suddenly, the press came down and caught his right hand. There was a 0.5-in. in diameter recessed button on the solenoid which was located on the bottom part of the press. This button was used to inch the press during set-up. The supervisor believed that Employee #1 used this button and the press came against some lock pins. As the pressure built, the press slipped off the lock pin and fell on Employee #1's hand. The employer had failed to reenergize the press and to block it to prevent its movement.

Keywords: PIN, POWER PRESS, FINGER, GUARD, CLEANING, SLIP, CAUGHT BY, CRUSHED, POINT OF OPERATION, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126138783 Hospitalized injury Fracture Numerical control machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close