Powered by GoogleTranslate

Inspection Detail

Inspection: 126122936 - La Bart Corporation.

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 126122936
Report ID: 0950644
Date Opened: 06/05/1997

Site Address:
La Bart Corporation.
1415 E. 9th Street
Pomona, CA 91766

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7538

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/16/1997

Emphasis:

Case Closed: 08/24/2000


Related Activity
Type Activity Nr Safety Health
Accident 362265860
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 2 3 5
Initial Penalty $9,000 $0 $0 $500 $0 $9,500
Current Penalty $3,625 $0 $0 $750 $0 $4,375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 10/16/1997 06/05/1997 $250 $250 $0 -  
2. 01002 Other 461 A 10/16/1997 10/31/1997 $250 $250 $0 -  
3. 02001 Other 3203 A 10/16/1997 10/31/1997 $250 $3,000 $0 12/08/1997 J - ALJ Decision  
4. 03001 Serious 3305 H 10/16/1997 10/31/1997 $3,000 $3,000 $0 12/08/1997 J - ALJ Decision  
5. 04001 Serious 5417 B 10/16/1997 10/31/1997 $625 $3,000 $0 12/08/1997 J - ALJ Decision  

Investigation Summary

Investigation Nr: 170898951
Event: 05/29/1997
Employee injured when truck air compressor explodes

At approximately 2:00 p.m. on May 29, 1997, Employee #1, of the La Bart Corporation in Pomona, CA, was testing a truck's air conditioning condenser unit for leaks. At first, he used compressed air from the shop's air compressor system but the pressure was inadequate. Employee #1 had began to use compressed oxygen along with the compressed air through a manifold/hose system when the air compressor of the truck's air conditioning unit exploded. Employee #1 sustained serious injuries and burns when he was struck by flying pieces of debris. Apparently, parts of the air conditioning unit had been cleaned with gasoline earlier that day.

Keywords: OXYGEN, AUTOMOTIVE REPAIR, FLAMMABLE VAPORS, AIR CONDITIONER, WORK RULES, COMPRESSED AIR, EXPLOSION, STRUCK BY, FLYING OBJECT, GASOLINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126122936 Hospitalized injury Burn/Scald(Heat) Automobile mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close