Inspection Detail
Inspection: 126103225 - Sbc Pacific Bell
Inspection Information - Office: Los Angeles District Office
Site Address:
Sbc Pacific Bell
1316 S Kenmore Avenue
Los Angeles, CA 90006
Mailing Address:
2445 Daly Street Room #107, Los Angeles, CA 90031
Union Status: Union
SIC:4813
NAICS: 517110/Wired Telecommunications Carriers
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/06/2005
Emphasis:
Case Closed: 01/06/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362589160 |
Investigation Summary
A 45-year-old service technician was installing telephone service at a work site. She climbed a 9.1-meter-tall utility pole to tap the telephone box. A crossarm supporting a thee-phase overhead power line was located at the top of the pole. The box was 1.5 meters below the power line. About a half hour after she started working, the employee was found slumped over, held by her safety belt about 5.5 meters above the ground. Emergency medical services personnel lowered the unconscious employee, but were unable to revive her. The medical examiner determined that the employee died from a cardiac arrest.
Keywords: OVERHEAD POWER LINE, TELECOM WORK, CARDIAC ARREST, UTILITY POLE, COMMUNICATION WORKER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126103225 | Fatality | Other | Telephone line installers and repairers |
Translate