Powered by GoogleTranslate

Inspection Detail

Inspection: 126086446 - Lofti Kakish Dba Ohm'S Electric

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 126086446
Report ID: 0950644
Date Opened: 04/09/2002

Site Address:
Lofti Kakish Dba Ohm'S Electric
936 E Haltern Ave
Azusa, CA 91702

Mailing Address:
1439 N Mulberry Ave, Upland, CA 91768

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/11/2002

Emphasis: S:Construction (Cship)

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362553042
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 1 3 4
Initial Penalty $16,200 $0 $0 $675 $0 $16,875
Current Penalty $10,800 $0 $0 $0 $0 $10,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 A 07/12/2002 08/06/2002 $0 $150 $0 F - Formal Settlement  
2. 01002 Other 23950051 A01 07/12/2002 08/06/2002 $0 $225 $0 08/01/2002 F - Formal Settlement  
3. 01003 Other 342 A 07/12/2002 07/22/2002 $0 $300 $0 08/01/2002 F - Formal Settlement  
4. 02001 Serious 23200004 A 07/12/2002 07/22/2002 $10,800 $10,800 $0 08/01/2002 F - Formal Settlement  
5. 03001 Serious 23200005 A01 07/12/2002 07/22/2002 $0 $2,700 $0 08/01/2002 F - Formal Settlement Citation has been deleted.
6. 04001 Serious 23200001 A 07/12/2002 07/22/2002 $0 $2,700 $0 08/01/2002 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 201795499
Event: 04/04/2002
Employee electrocuted in crawl space while installing fan

On April 4, 2002, Employee #1, an electrician's assistant, was installing a ceiling fan in the bathroom of a residence. He was working alone in the attic crawl space when the supervisor, a son of the company owner, said that he heard a groan and then the sound of the employee falling down. The supervisor told the homeowner to cut the power and to call 911. Employee #1 was killed. The Los Angeles County Coroner's Report #02-02658, stated that burn wounds were present on his right hand and left breast, consistent with a low-voltage electrocution. The attic crawl space was reportedly very hot and body moisture via perspiration may have been a factor. The power to the house was on via a newly installed 200-amp service breaker box. The employer, a family-owned electrical contrator, said it was possible that the system became energized through a jumper lead tied to a stack switch in the bathroom in which the fan was being installed. There was, apparently, no means of shutting off power to the circuit being worked on to protect it from being accidentally energized. The supervisor denied having exact knowledge of what job Employee #1 was doing at the time of the accident. Employee #1 was not a licensed electrician, nor a journeyman with any union. He had been with the company for about one year but did not have any previous experience in electrical work. After an investigation, the employer was cited for violations, general, of T8CCR 1509(a), Injury and Illness Prevention Program, and T8CCR 2395.51(a)(1,) effective grounding of equipment; for a violation, regulatory, of T8CCR 342(a), reporting work-connected fatalities and serious injuries; violations, serious, of T8CCR 2320.5(a)(1), authorized person responsibility around re-energized systems, and T8CCR 2320.1(a) work procedures/work by qualified personnel; and a violation, serious/accident-related, of T8CCR 2320.4(a), de-energized equipment or systems/lockout-tagout.

Keywords: BURN, WORK RULES, ELECTROCUTED, CONSTRUCTION, ELECTRICAL WORK, LOCKOUT, INEXPERIENCE, ELEC CIRC PART--MISC, CRAWL SPACE, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126086446 Fatality Electric Shock Electricians' apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close