Inspection Detail
Inspection: 126082809 - Jazz Semiconductor Inc
Inspection Information - Office: Santa Ana District Office
Site Address:
Jazz Semiconductor Inc
4321 Jamboree Rd
Newport Beach, CA 92660
Mailing Address:
, , 00000
Union Status: Union
SIC:3674
NAICS: 334413/Semiconductor and Related Device Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 06/24/2003
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 06/24/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362364242 |
Investigation Summary
On January 21, 2003, Employees #1 and three coworkers were working to increase the flow rate of ozone to a quick dump rinse station on an automated wet bench. The wet bench had a local exhaust ventilation plenum engineering control for normal operation. One coworker was observing the remedial activity and another coworker had left the room. Either Employee #1 or the coworker assisting Employee #1 reached inside the plenum through the open plenum door to move a line to obtain a better view. A previously disconnected ozone supply line shifted, pointed directly into the face of Employee #1 and delivered the full flow of ozone onto his face. Employee #1 and the coworker both suffered respiratory irritation and Employee #1 was hospitalized. The original narrative did not specify the medical treatment for the coworker.
Keywords: RESPIRATORY, MAINTENANCE, ASPHYXIATED, RESPIRATORY TRACT, OVEREXPOSURE, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126082809 | Hospitalized injury | Asphyxia | Machinery maintenance occupations |