Inspection Detail
Inspection: 126061332 - Stuart Dean Co
Inspection Information - Office: Los Angeles District Office
Site Address:
Stuart Dean Co
1100 S Grand Disney Concert Hall
Los Angeles, CA 90012
Mailing Address:
11823 Sherman Way, North Hollywood, CA 91605
Union Status: Union
SIC:3471
NAICS: 332813/ Electroplating, Plating, Polishing, Anodizing, and Coloring
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/05/2003
Planning Guide: Safety-Construction
Emphasis: S:Construction (Cship)
Case Closed: 11/07/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362579229 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $370 | $0 | $370 |
| Current Penalty | $0 | $0 | $0 | $370 | $0 | $370 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3294 I | 12/03/2003 | 12/08/2003 | $185 | $185 | $0 | - | ||
| 2. | 01002 | Other | 3295 C01 F | 12/03/2003 | 12/08/2003 | $185 | $185 | $0 | - |
Investigation Summary
On June 5, 2003, Employee #1 and a coworker were cleaning the exterior steel of a building. This is accomplished through the use of a site-unique suspended scaffold, designed and engineered by Skymaster Corporation. Employee #1 and a coworker were in the process of moving the scaffold. The scaffold is suspended by an arm that rides on a tracked trolley. The trolley rides on a pair of rails that are 10 in. in diameter. The track goes around the periphery of the roof which is high on the north and south faces, and lower on the east and west faces. The trolley was being traversed from the southeast face around a corner where a 14 degree slope began decent to the middle of the east face, then back uphill to the northeast face. Employee #1 was riding in the scaffold and the coworker was operating the electric motor controls from the roof, along side the scaffold. As it began to descend the trolley began to slide on the rails, it gained speed until it reached the bottom of the slope then continued to slide uphill 35 ft, where the scaffold began to swing to the side. At this time Employee #1 was ejected from the scaffold, but was held to the scaffold by his fall protection harness. As he and the scaffold swung sideways the scaffold contacted some of the steel walls whose edges were sharp. This sliding along the walls cut the fall protection lanyard, causing the Employee #1 to fall approximately 2 ft to a structural glass ceiling. He received minor bruises and a small cut on his forehead. He was not hospitalized.
Keywords: FOREHEAD, FALL, FALL PROTECTION, CONTUSION, SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126061332 | Non Hospitalized injury | Bruise/Contus/Abras | Construction laborers |