Inspection Detail
Inspection: 126060979 - 8th And Alameda Public Scales
Inspection Information - Office: Los Angeles District Office
Site Address:
8th And Alameda Public Scales
800 S Alameda Street
Los Angeles, CA 90021
Mailing Address:
800 S Alameda Street, Los Angeles, CA 90021
Union Status: NonUnion
SIC:4785
NAICS: 488490/Other Support Activities for Road Transportation
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/14/2004
Emphasis:
Case Closed: 09/13/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362581811 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $2,250 | $0 | $0 | $250 | $0 | $2,500 |
| Current Penalty | $2,250 | $0 | $0 | $250 | $0 | $2,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A | 10/15/2004 | 12/03/2004 | $125 | $125 | $0 | - | ||
| 2. | 01002 | Other | 3400 B | 10/15/2004 | 12/03/2004 | $125 | $125 | $0 | - | ||
| 3. | 02001 | Serious | 4650 M | 10/15/2004 | 10/20/2004 | $2,250 | $2,250 | $0 | - |
Investigation Summary
At 8:08 a.m. on April 16, 2004, Employees #1 and #2 were working at 8th and Alameda Public Scales in Los Angeles, CA. The site is a public scale that is used to weigh semi tractor trailers. In addition they have a propane dispensing facility. Across the street is the Los Angeles vegetable mart that has many propane-powered forklifts that 8th and Alameda Public Scales dispenses propane to. The propane company fills the main tank at 8th and Alameda Public Scales twice a day. A customer brought six propane tanks in to have them refilled. He brought them in a 2.5 ton truck with a box cargo area. Employee #1 was refilling the propane tanks in the bed of the truck, and had the rear door open. Prior to refilling, Employee #2 opened the valves on the tanks to purge them. This allowed residual propane to "pool" in the back of the truck. As he started to fill the tanks Employee #2 activated an electric pallet jack which provided an ignition source, causing a flash fire. At least one of the tanks started to burn. Employee #1 retrieved a fire extinguisher and put out the fire. Employees #1 and #2 received first and second degree burns to their arms and faces.
Keywords: BURN, FLAMMABLE LIQUID, WORK RULES, FIRE, PROPANE, SPARK, ARM, FACE, JACK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126060979 | Non Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction |
Translate