Inspection Detail
Inspection: 126059088 - Gibbons Ltd.
Inspection Information - Office: Los Angeles District Office
Site Address:
Gibbons Ltd.
2911 Winona Avenue
Burbank, CA 91509
Mailing Address:
, , 00000
Union Status: Union
SIC:7819
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/18/2002
Emphasis:
Case Closed: 12/27/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362615346 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $0 | $0 | $0 | $625 | $0 | $625 |
| Current Penalty | $0 | $0 | $0 | $625 | $0 | $625 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 12/19/2002 | 12/24/2002 | $250 | $250 | $0 | - | ||
| 2. | 01002 | Other | 461 A | 12/19/2002 | 02/07/2003 | $250 | $250 | $0 | - | ||
| 3. | 03001 | Other | 3203 A | 12/19/2002 | 02/07/2003 | $125 | $125 | $0 | - |
Investigation Summary
On June 28, 2002, Employee #1, a gunsmith, was testing a muzzel loading flintlock musket. He loaded it, with just a powder charge only, primed the flash pan, and test fired it without a projectile. The propellent was black powder and was kept in a flask. After test firing, Employee #1 immediately reloaded from the flask, which caused an ignition from a spark. He suffered second-and third-degree burns on his hands, right forearm and face. He was hospitalized to treat his burns.
Keywords: BURN, POWDER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126059088 | Hospitalized injury | Burn/Scald(Heat) | Helpers, mechanics and repairers |